Skip to main content

Tender Notice for Bid - Supply, Delivery & Installation of Ict Infrastructure: Server, Storage, Network Equipment & UPS

Prime Insurance Ltd and Prime Life Insurance Ltd

Prime Insurance Ltd and Prime Life Insurance Ltd are insurance companies accredited by the National Bank of Rwanda to provide short-term and life insurance.

Rate this employer
Average: 4.5 (11 votes)

OPEN TENDER– REQUEST FOR PROPOSALS (RFP)

Tender Reference No.: 003/PLI/PI/ICT/OT/2026/INF
Tender Type: OPEN TENDER (Invitation to Specific Companies)
Tender Name: Supply, Delivery & Installation of ICT Infrastructure: Server, Storage, Network Equipment & UPS
Issue Date: 20/05/2026
Closing Date & Time: 29/05/2026 @ 15:30
Contact for Clarifications: Dieudonné UWAMBAJIMANA | dieudonne.uwambajimana@prime.rw | 0786 138 376
Companies PRIME LIFE INSURANCE LTD & PRIME INSURANCE LTD

1. Background

Prime Life Insurance Ltd and Prime Insurance Ltd (hereinafter referred to as "the Companies") are regulated insurance companies based in Kigali, Rwanda. As part of an ongoing ICT infrastructure upgrade, the Companies invite eligible bidders to submit proposals for the supply, delivery, installation, and commissioning of a comprehensive set of ICT equipment and services.

The scope of supply includes one high-performance rack server and two dual-controller all-flash NVMe storage units, each with a minimum of 20 TB usable capacity configured in RAID 6, along with all connectivity accessories required to achieve a minimum host-to-storage throughput of 10 Gb/s. The networking infrastructure to be supplied comprises two Cisco MDS 9148S 16G Fibre Channel SAN switches, one Cisco Catalyst 1300-48P-4X managed switch, and one Cisco Catalyst 9300-48P-E managed switch. In addition, one 20 kVA online double-conversion UPS is required to ensure continuous power protection for the environment. Full on-site installation, configuration, and commissioning of all supplied equipment is included in the scope of work. All equipment must be new, genuine, and procured through an authorized reseller.

The new storage infrastructure will serve a total of three host servers: two existing Dell PowerEdge R750 servers already in operation at the Companies' premises, and the one new rack server to be supplied and commissioned under this tender.

2. Scope of Supply & Deliverables

Bidders must propose equivalent or superior products from one of the following approved brands:

DELL, HP, Huawei, Lenovo, Sisco

The complete scope covers:

  • Component A – One (1) high-performance rack server fully configured per the BOM in Section 3.
  • Component B – Two (2) dual-controller all-flash NVMe storage systems per the BOM in Section 4, each delivering ≥ 20 TB usable capacity (RAID 6, expandable).
  • Component C – All connectivity accessories (cables, transceivers, switch) required to interconnect the new server and both existing Dell PowerEdge R750 servers to both storage units at ≥ 10 Gb/s per path.
  • Component D – Network Equipment: two (2) Cisco MDS 9148S 16G Fibre Channel SAN switches (24 active ports each, with On-Demand Port Activation License), one (1) Cisco Catalyst 1300-48P-4X 48-port PoE+ managed switch, and one (1) Cisco Catalyst 9300-48P-E 48-port enterprise stackable switch, all with applicable licenses, per the BOM in Section 6.
  • Component E – UPS: one (1) 20kVA / 20kW online double-conversion Uninterruptible Power Supply (APC or approved equivalent) for data centre power protection, per the BOM in Section 7.
  • On-site installation, rack mounting, cabling, RAID/pool configuration, SAN zoning, network switch configuration, UPS installation and commissioning, and host mapping for all three (3) servers.
  • Integration testing, performance validation, and full handover documentation.
  • Multi-year technical support and warranty as specified.

3. Server Minimum Specifications (Quantity: 1 Unit)

The server shall meet or exceed the configuration below. Bidders proposing an alternative brand must include a line-by-line specification equivalence table.

# Part No. Model / SKU Description Qty
1 0231YFNL 2288 V8-S8AAF Server Chassis – 2288 V8 (8×2.5" SAS/SATA Drive Pass-Through Chassis) 1
2 02313XSF PAC900S12-B2 Server Platinum 900W AC Power Supply v2.0 (ST) 2
3 0253YAEX BC6515PCPU2U01 Intel Xeon 6515P (2.3 GHz / 16-Core / 72 MB / 150 W) Processor with 2U Standard Heatsink 2
4 0251Y287 M564R32 DDR5 RDIMM 32 GB, 288-pin, 6400 MHz, 1.1 V, ECC, 2-Rank (2 G×8-bit) 8
5 0255YEYT SE006960GV7S1 SSD 960 GB, SATA 6 Gb/s, Read Intensive, SE006 Series, 2.5-inch 2
6 0256Y174 9560-8i 4G PCIe RAID Card – 9560-8i 4G 1
7 0258Y575 BC16M01PRUKA Riser Module – 2×8X SLOT (PCIe 5.0) IO1 & IO2 1
8 0302Y237 XC331 OCP 3.0 Ethernet Adapter – 10 GbE (BCM57416) Dual-Port RJ45, PCIe 3.0 ×8 1
9 0405Y017 XC-0405Y017 High-Speed Cable – Slimline 2×mini SAS HD, 0.8 m & 0.7 m 1
10 21243789 SR_787X43_8X7_5 Ball Bearing Rail Kit 1
11 2120Y422 2120Y422_DRAEN Air Duct (2U Radiator) 1
12 0231Y191 BC1M22FAN 8038+ Fan Module 4
13 04040890 CC13UK300 Power Cable – UK AC 250 V/10 A, 3.0 m, C13SF (Wall Plug) 2
14 0405G019 CC13EU180 Power Cord – EU AC 250 V/10 A, 1.8 m, C14SM–C13SF (PDU) 2
15 88134ULC-700 0231YFNL_36M Super-Care Onsite Standard Technical Support – 2288 V8 – 36 Months 1

Reference platform: Huawei FusionServer Pro 2288 V8 (or equivalent from DELL / HP / Lenovo).

4. Storage System Minimum Specifications (Quantity: 2 Dual-Controller Units)

Each storage unit shall be a dual-controller all-flash NVMe array configured for ≥ 20 TB usable capacity under RAID 6, with at minimum one (1) hot-spare disk, and shall be field-expandable for future capacity growth.

  • Disk Sizing Rationale

Disk Type 3.84 TB NVMe SSD
RAID Level RAID 6 (8 data + 2 parity disks)
Hot Spare 1 disk
Disks per Unit 11 disks (8 data + 2 parity + 1 hot spare)
Raw Capacity per Unit 11 × 3.84 TB = 42.24 TB raw
Usable Capacity per Unit ~24 TB usable (8 data disks × 3.84 TB × 0.8 efficiency factor) — exceeds 20 TB minimum
Total Disks (2 units) 22 disks (11 per unit × 2)
Expandability Field-expandable via additional drive enclosures without disruption to live data
# Part No. Component Specification Qty
1 D3V7N-2C128G-O OceanStor Dorado 3000 Dual-Controller All-Flash Array (2U, Dual Ctrl, NVMe, AC/240V HVDC, 128 GB Cache, 8×1 GbE + 8×10 GbE, SPE62C0225, V7) 2
2 V7S4×10GE SmartIO Module 4-Port DPU-Based SmartIO I/O Module (SFP+, 10 GbE) – per unit 2
3 D3V7-NVMe3.84 3.84 TB NVMe SSD 3.84 TB SSD NVMe Palm Disk (2.5") – RAID 6, 8 data + 2 parity + 1 hot spare = 11 disks → ~20 TB usable per unit. Field-expandable. 22
4 D3V7-LBS-AllSoftware SAN License Bundle SAN Software Bundle: Thin Provisioning, Snap, Replication, Clone, QoS, Erase, DME IQ, Virtualization, Metro, CDP – per unit 2
5 D3V7-LBS-UltraPath UltraPath SAN UltraPath SAN Client License – per unit 2

Reference platform: Huawei OceanStor Dorado 3000 V7 (or equivalent from DELL / HP / Lenovo).

The storage units must support direct connectivity (iSCSI or FC at ≥ 10 Gb/s) to: the one (1) new server, and both existing Dell PowerEdge R750 servers.

5. Connectivity Accessories (Minimum 10 Gb/s Throughput per Path)

All accessories required to achieve full host-to-storage connectivity at ≥ 10 Gb/s must be quoted. The table below lists the minimum required items. Bidders must verify compatibility with the proposed server, storage, and existing Dell PowerEdge R750 HBA/NIC ports and include any additional items necessary for a complete, production-ready installation.

# Part No. Item Description / Purpose Qty
1 10/25 GbE SFP+ DAC Cable Direct Attach Copper (DAC) Cable, SFP+, 10 GbE, 3 m – for server-to-storage links (new server ↔ Storage 1 & Storage 2) 4
2 10/25 GbE SFP+ DAC Cable Direct Attach Copper (DAC) Cable, SFP+, 10 GbE, 3 m – for existing Dell PowerEdge R750 host links (2× R750 ↔ Storage 1 & Storage 2) 8
3 10 GbE SFP+ Transceiver (SFP+) 10GBASE-SR SFP+ Optical Transceiver, Multi-Mode, LC Duplex – for storage controller ports (as required per switch topology) 8
4 SN2F02FCPC OM3 Fibre Patch Cord Patch Cord DLC/PC–DLC/PC, Multi-Mode OM3, 10 m, 2 mm, Bending-Insensitive – per storage unit (×2 units) 4
5 10 GbE Top-of-Rack Switch 10 GbE / 25 GbE Managed ToR Switch (minimum 24 SFP+ ports) – to interconnect new server, 2× Dell R750, and 2× storage units at ≥10 Gb/s per path 1
6 SFP+ to RJ45 Transceiver 10GBASE-T SFP+ Copper Transceiver – for existing Dell R750 10 GbE RJ45 HBA ports connecting to the switch (if applicable) 4
7 Cat6A Ethernet Patch Cable 3m Cat6A Shielded Patch Cable, 3 m – management / out-of-band connections for storage controllers 4
8 Rack Cable Management (1U) 1U Horizontal Cable Manager / Lacing Panel – rack tidiness and cable strain relief 2

Note: Bidders must confirm the network topology diagram in the Technical Proposal (Section 8.3), showing all three hosts connected to both storage units with redundant paths.

6. Network Equipment Minimum Specifications

All network equipment must meet or exceed the specifications below. Bidders proposing equivalent models must submit a line-by-line compliance table.

CISCO MDS 9148S – 16G Fibre Channel SAN Switch (Qty: 2 units)
Type Fibre Channel SAN Fabric Switch, 1RU Form Factor 1RU rack-mountable, tower-convertible
FC Ports 48 x autosensing FC ports (hardware) Active Ports 24 active ports (On-Demand Port Activation License incl.)
Port Speed 16 Gbps per port (autosensing 2/4/8/16G) Transceiver SFP+ (16G SW/LW SFP+ transceivers)
Fabric Bandwidth 768 Gbps aggregate switching capacity OS Cisco NX-OS
HA Features Dual redundant hot-swap PSU & fans; ISSU (non-disruptive upgrades) Security FIPS 140-2; port security; fabric binding
SAN Features VSAN, zoning, PortChannel, FCIP, iSLB Mgmt CLI, Cisco DCNM/Nexus Dashboard, SNMP
License On-Demand Port Activation License (12-port increment to activate 24 ports) incl. Warranty Minimum 1-year hardware warranty; SMARTnet recommended
CISCO CATALYST 1300-48P-4X – Managed PoE+ Switch (Qty: 1 unit)
Model C1300-48P-4X Type Layer 3 managed switch, 1RU
Copper Ports 48 x 10/100/1000 Mbps PoE+ (802.3af/at) PoE Budget 370 W total PoE power budget
Uplink Ports 4 x 10G SFP+ uplinks Switching Cap. 104 Gbps switching capacity
OS Cisco IOS Linux-based L3 Features Static routing, RIP, OSPF, ACL
Security 802.1X, DHCP snooping, ARP inspection, IP source guard Management Web GUI, CLI (SSH/Telnet), SNMP v1/v2c/v3
License Included (no additional subscription required) Warranty Minimum 1-year limited hardware warranty
CISCO CATALYST 9300-48P-E – Enterprise Stackable Switch (Qty: 1 unit)
Model C9300-48P-E Type Layer 3 enterprise stackable switch, 1RU
Copper Ports 48 x 10/100/1000 Mbps PoE+ (802.3af/at) PoE Budget 715 W Platinum PSU
Uplink Module Modular uplink slot (10G/25G/40G SFP+ network module) Stacking StackWise-480 – up to 8-unit stack, 480 Gbps bandwidth
OS Cisco IOS XE L3 Features Full L3 routing; SD-Access ready
Security MACsec AES-256, 802.1X, IBNS 2.0, ETA (Encrypted Traffic Analytics) Management Cisco DNA Center, CLI, NETCONF/YANG, SNMP
ISSU In-Service Software Upgrade (non-disruptive) License Network Advantage license included
Warranty Minimum 1-year hardware warranty; DNA/C1 support recommended

Note: All switches must be supplied with applicable licenses activated and factory-configured for integration into the data centre environment.

7. UPS Minimum Specifications

The UPS must meet or exceed the specifications below. Bidders proposing an alternative brand (Huawei, Eaton, Vertiv, Emerson, etc.) must include a line-by-line compliance table and current product datasheet.

UPS – 20 kVA / 20 kW Online Double-Conversion (Qty: 1 unit)
Reference Model APC Smart-UPS On-Line SRTG20KXLI (or approved equivalent) Type Online double-conversion (VFI), pure sine wave
Capacity 20 kVA / 20 kW Power Factor Unity (VA = W) – no derating
Input Voltage 160–285 V single-phase OR 380–415 V 3-phase (user-selectable) Input Frequency 40–70 Hz auto-sensing
Output Voltage 220 / 230 / 240 V selectable (default 230 V) Output Frequency 50/60 Hz ±4 Hz (±0.1 Hz in battery mode)
Form Factor 7U rack / tower convertible Transfer Time Zero (online double-conversion)
Battery Type Sealed VRLA lead-acid (maintenance-free) Battery Voltage ±192 V nominal
Recharge Time 4 hours to 90% capacity Battery Life 3–5 years expected life
Runtime (ext.) Up to 4 external battery packs for extended runtime Efficiency >98% Green Mode; >93.5% online mode
Bypass Internal automatic & manual bypass EPO Emergency Power Off (EPO) terminal
Management Pre-installed Network Management Card (SNMP/Web/Modbus) Connectivity USB, serial (RJ45), SmartSlot for additional cards
Software PowerChute Network Shutdown (graceful OS shutdown) Alarms Audible + visual (LCD display); email/SNMP trap
Warranty 3-year electronics / 2-year battery (minimum) Standards IEC 62040-1, IEC 62040-2; CE, UL listed

Note: UPS must be installed, commissioned, and tested on-site by a certified engineer. Battery runtime test report must be submitted at handover.

8. Technical Proposal Requirements

The Technical Proposal must contain, at minimum:

  • Full technical datasheets for each proposed component, mapped line-by-line to the minimum specifications in Sections 3–7.
  • Specification equivalence table comparing proposed items against each BOM line item.
  • Network connectivity / topology diagram showing how both storage units connect to the new server and both existing Dell PowerEdge R750 servers (redundant paths, VLAN/zoning plan), including SAN fabric layout for the MDS 9148S switches and LAN topology for the Catalyst 1300 and 9300 switches.
  • RAID/pool configuration plan: disk count, RAID level, hot-spare policy, usable capacity calculation, and expansion roadmap.
  • Installation and commissioning methodology with a project plan and timeline in working days, covering server, storage, network switches (SAN fabric zoning, LAN VLAN configuration), and UPS installation.
  • Proof of authorised reseller / partner status for the proposed brand (current certificate or manufacturer letter).
  • Minimum two (2) reference projects of comparable scope (server + SAN storage + network switching) completed within the last three (3) years, including client name, value, and contact.
  • Warranty and after-sales support plan, including on-site response time, spare-parts availability, and escalation procedures.

9. Financial Proposal Requirements

The Financial Proposal must be submitted in a separate sealed envelope and must include:

  • Lump-sum price for each component (A–F) in Annex A, with a detailed cost breakdown attachment for any component requiring itemised sub-pricing.
  • Installation and commissioning itemised per task.
  • Any additional accessories or consumables not listed but required for a complete installation.
  • Prices in RWF.
  • VAT shown separately (exclusive and inclusive totals).
  • Delivery and commissioning timeline from purchase order issuance.
  • Payment terms proposed.

Bidders must complete and submit the Financial Proposal Template in Annex A.

10. Bidder Eligibility Requirements

Bidders must provide:

  • Valid RDB Company Registration Certificate.
  • Valid Tax Clearance Certificate 
  • Proof of authorised partnership / reseller status for the proposed brand.
  • Minimum two (2) reference letters or signed contracts for similar infrastructure projects completed within the last three (3) years.

11. Bid Evaluation & Selection Criteria

Bids will be evaluated using the following weighted criteria:

# Evaluation Criterion Weight
1 Cost Optimisation – best value, competitive pricing, total cost of ownership 40%
2 Technical Specification Compliance – meeting or exceeding minimum specs stated in Sections 3–7 30%
3 Technical Experience – proven track record in comparable server & storage projects 10%
4 Brand Partnership – valid authorised reseller / partner certificate for proposed brand 10%
5 After-Sales Support & Warranty – SLA response time, warranty terms, local support 5%
6 Delivery Timeline – ability to deliver and commission within agreed schedule 5%
TOTAL 100%

The Companies reserve the right to request clarifications, conduct site visits, or seek additional information during the evaluation process.

12. Submission Requirements

Bidders must submit:

  • One (1) sealed envelope containing: Technical Proposal + all eligibility documents.
  • One (1) sealed envelope containing: Financial Proposal (completed Annex A).
  • Both envelopes inside one outer sealed envelope, clearly labelled:
Prime Life Insurance Ltd & Prime Insurance LtdMIC Building, KN2 Av, Kigali – Rwanda | Second FloorTel: 0788 150 100 | Toll-free: 1320 | info@prime.rw
Tender Ref: 003/PLI/PI/ICT/OT/2026/INFSupply, Delivery & Installation of ICT Infrastructure | 003/PLI/PI/ICT/OT/2026/INFDO NOT OPEN BEFORE: 29/05/2026 @ 15:30

13. Clarifications

All clarification requests must be submitted in writing no later than 27/05/2026 to:

Dieudonné UWAMBAJIMANA

Email: dieudonne.uwambajimana@prime.rw | Tel: 0786 138 376

Prime Insurance Ltd and Prime Life Insurance Ltd (hereinafter referred to as “the Companies”) reserve the right, at their sole and absolute discretion, to accept or reject any bid, in whole or in part, without assigning any reason, and to annul the tender process at any stage prior to contract award. This statement forms an integral and binding part of the referenced open tender, and submission of a bid shall constitute full and unconditional acceptance of all terms and conditions herein. The Companies further reserve the right to cancel the tender at any time before award without liability or obligation to compensate bidders for any costs incurred, to postpone, suspend, or extend the bid submission deadline with or without prior notice and for any reason, to re-issue the tender in whole or in part under the same or revised terms, and to phase the implementation of the awarded scope across the 2026 and 2027 financial periods, subject to budget availability, internal approvals, and operational requirements at the time of award.

_______________________________Col (Rtd) Eugene M. HAGUMAChief Executive OfficerPRIME INSURANCE LTD _______________________________HABARUREMA InnocentChief Executive OfficerPRIME LIFE INSURANCE LTD
Click on the APPLY button to send your application documents:
  • Your application will be sent to the employer immediately (Allowed formats: .doc .pdf .txt .docx)
  • A confirmation email will be sent to you few minutes afterwards
  • You can request any documents archived from our website (ex: a job description, a CV, a cover letter...)