Skip to main content

Tender Notice for the Supply of Medical Equipment and Materials at King Faisal Hospital Rwanda Foundation

King Faisal Hospital Rwanda Foundation (KFHRF)

The King Faisal Hospital Rwanda Foundation is currently at its beginning stage following an action plan that was approved by the hospital in October, 2020.

Within the health domain, the Foundation’s major objectives will be to support researchers through funding, training and facilitation in dissemination of research data, establishing strategic relationships with academic, research-driven and research sponsoring institutions and supporting training for medical researchers.

As part of a social welfare that constitutes an integral part of the foundation, the hospital will financially assist patients who cannot afford medical care and will continue to sensitize the public on NCDs, congenital and surgical diseases for prevention and early consultation.

Furthermore, the foundation will support surgical camps/outreach within the country in a bid to reduce long waiting lists in teaching hospitals. Finally, within the education domain, the foundation will be promoting new learning tools including e-learning and support Continuing Medical Education (CME).

Rate this employer
Average: 4 (45 votes)

TENDER NOTICE:

SUPPLY OF MEDICAL EQUIPMENT AND MATERIALS AT KING FAISAL HOSPITAL RWANDA FOUNDATION

Date of Issue: July 28th, 2025

Deadline for Submission: August 11th, 2025

King Faisal Hospital Rwanda Foundation (KFHRF) is seeking interested and qualified companies to submit bids for the supply of medical equipment and materials.

Eligible offers must include the following information to be considered:

  • Priced Proposal,
  • Validity of the offer,
  • Copy of the company’s Certificate of Registration, tax clearance certificate, VAT registration, RSSB clearance and trading license
  • 3 certificates of good completion of the similar work

Proposals should be submitted in English, offers in Rwandan francs, addressed to the Executive Secretary, and submitted to rutavogerwa.j@kfhkigali.com by Monday, 11h August, 2025 at 10:00 AM Central Africa Time (CAT). Please note this tender notice is not a binding contract.

Done in Kigali, Rwanda on July 28th, 2025

Ms. Kara Neil

Executive Secretary

King Faisal Hospital Rwanda Foundation

No

Description and specifications

Qty

1

Venturi Suction regulators with 2L suction bottles

32

2

DIN standard Oxygen flowmeter with humidifier bottle

32

3

Central Control Monitoring - Physiologic Monitoring System, Acute Care (With Computers, 43’’lcd Screens And Full Connectivity Accessories)

1

4

Patient monitor

5

5

Manual Hospital beds 3 functions with mattress

7

6

Cabinets, Bedside

24

7

Overbed Table Height Adjustable

17

8

Drip stand

20

16

Paediatric weighing scale

2

9

Mobile LED Operating light Ceiling

1

10

Dressing packs

10

11

Stitch pack

5

12

Abscess pack

3

13

Examination lamp

2

14

Working, instrument trolley

7

15

Adult weighing scale seating type (Big size)

2

17

Stool

2

18

Theatre trolleys (Different sizes)

3

19

Portable oximeter (Handheld Portable Vital signs Patient Monitor)

6

20

10 L Portable Oxygen cylinder with oxygen regulator and trolley

4

21

Oxygen regulator

5

22

Theatre bins

10

23

Spinal scoop board

2

24

Splints for legs

10

25

Splints for arms

10

26

Head immobilizer

3

27

Commode chair

2

28

Urinal for men

4

29

Vein finder

2

30

Bed pan

4

No

TECHNICAL SPECIFICATIONS

REQUIRED

QTY

1

MANUAL PATIENT BED 3 FUNCTIONS WITH MATTRESS

Purpose of use: To provide safety, comfort and mobility for hospitalized patients in need of health care.

Main Feature:

  • Backrest, Footrest and Trendelenburg movements by 3 cranks/3 movements manual operation
  • Epoxy-coated mild steel bed frame
  • 3 section bed board
  • Detachable head/footboard with easy lock
  • ABS side rails with angle indicator
  • ABS head and footboard with holes for moving the bed easily
  • Diameter of 125mm noiseless castors, all with individual brakes
  • Bumper castors on 4 corners for protection
  •  Should have Collapsible side rails not aluminum alloys 

Accessories:

  • IV pole with adjustable height
  • Drainage hooks at the side of the bed

Specification:

  • Overall size(L*W*H)2160*960*500mm
  • Back section adjustable0-75°
  • Foot section adjustable 0-40°
  • Trendelenburg 0-12°
  • Caster Dia with breaks 125mm ( 5″ )
  • Safe working load 140-240 kg

Standards and Certifications:

CE Mark, MDD93/42/EEC, ISO13485

7

2

OVERBED TABLE HEIGHT ADJUSTABLE

1. BASIC REQUIREMENTS

1.1 An over bed table for Intensive care Patient.

1.2 Table, Overbed, Hi-Lo, Auto Rise, Mobile.

2. TECHNICAL SPECIFICATION:

2.1 The frame to be constructed from mild steel, either Nylon polyester or chip resistant epoxy coated paint. Colour to be confirmed.

2.2 The frame to be fitted with four 40-50mm swivelling castors of which two should be lockable.

2.3 The table top to be manufactured from Class 1 fire retardant laminate surface with edges rounded for safety.

2.4 The table to have easy height adjustment being lever operated.

2.5 The table to rise automatically when slight pressure is applied and automatically lock in place when lever released.

2.6 The table to be height adjustable from approximately 75 to 110cms. 

2.7 The table surface to be hard wearing, heat resistant and be easily cleanable.

2.8 The unit to confirm to all relevant international safety and CE standards for manufacture, safety and performance – Tenderer to specify relevant standards.

Extra set of castors must be provided

17

3

CABINETS, BEDSIDE

 1 The cabinet should have the following configurations:

 1.1 Solid wood cabinet edges

 1.2 Steel pedestal base for durability

 1.3 Internal steel frame

 1.4 Two Drawers and one cabinet

 1.5 Guardrail

 1.6 Mounted on four swivel castors, with locks

 1.7 Color to be selected by client

 1.8 Approx. dimensions: 750 x 500 x 400mm

24

4

Central control monitoring - PHYSIOLOGIC MONITORING SYSTEM, ACUTE CARE ( WITH COMPUTER and second 43’’LCD SCREENS AND FULL CONNECTIVTY ACCESSORIES)

1 The unit shall have the following minimum features:

2 Shall be fully functional for all patient categories: Adult, Pediatric and Neonate

3 Shall be fully modular system, i.e. separated CPU/modules server and display

4 The unit's parameter modules shall be swappable with other patient monitors in the hospital (same modules interface)

5 All surfaces shall be resistant to common disinfectants

6 Display/screen:

6.1 Screen size: minimum of 12” Medical grade, LCD color touch screen

6.2 Simultaneous display of 4 channels/waveforms

6.3 With preset and configurable interfaces/layouts

6.4 The order and color of waveforms and numerical parameters shall be user selectable

7 The unit shall include all the required software, modules, parts and accessories to monitor the following parameters:

7.1 ECG and Heart Rate

7.1.1 5 leads monitoring for adults and pediatric

7.1.2 3 leads monitoring for neonates

7.1.3 Heart rate range: 15 – 300bpm

7.2 Basic Arrhythmia detection and classification of different types of arrhythmias for adults and pediatrics

7.3 ST segment analysis: Advanced monitoring and analysis of ST segment deviation for adults and pediatrics

 7.4 SpO2 and Pulse Rate

 7.4.1 Range: 1 –100%

 7.4.2 Shall be compatible with sensors from other manufacturers, including Massimo, and Nellcor

 7.5 Respiration

 7.5.1 Respiration monitoring via impedance calculation, through ECGlead

 7.5.2 Range: 1 – 150bpm

 7.6 Temperature

7.6.1 1channel

 7.6.2 Range: 0 – 45°C

 7.7 Non Invasive Blood Pressure

 7.7.1 Oscillometricmethod

 7.7.2 With manual and automatic activation

 7.8 Invasive Blood Pressure

 7.8.1 Simultaneous measurement and display of 2channels

 7.8.2 Range: -25 to 360mmHg

 7.8.3 The appropriate interface cables and adapters between the patient monitor and pressure transducer shall be included (coordinate with the client

 8 The unit shall be capable (software ready) to monitor the following parameters:

 8.2 Cardiac Output

 8.2.1 Range: 0.5 – 15l/min

 8.2.2 Blood temperature range: 25 – 42°C

 8.2.3 Injectate temperature range: -1 –30°C

 8.3 12 lead ECG monitoring for adult and pediatric with ST analysis for all leads

 8.4 Additional 2 channels for invasive blood pressure

 9 With drug calculation and management capability

 10 Networking and connectivity

 10.1 Shall be fully compatible, connectable and interfaced with the anesthesia machine for bidirectional data sharing (interface shall be coordinated supplier)

 10.2 Shall be networkable to share data with hospital networks (bidirectional) such as Hospital Information System (HL7 compliant), Laboratory and PACS as well as with a central station via Local area Network (LAN) (coordinate with client and IT contractors)

 10.3 Shall facilitate report generation via networked printer and recorder

 11 Trending /Events storage:

 11.1 Numerical and graphical trending : 48 hours

 11.2 Events storage: 50 events

 12 Alarm/self test system:

 12.1 With advanced automatic self test at switch on

 12.2 With alarm history for 24 hours

 12.3 Prioritized (three alarm levels) with audio (tone coded) and visual (color coded) alarming system according to alarm level

 13 The unit, its accessories and modules shall be protected against defibrillation

14 Accessories (the following shall be included):

 14.1 Reusable ECG cables for adult, pediatric and neonate (x1 each)

 14.2 Disposable electrodes for adult, pediatric and neonate (x100 each)

 14.3 Reusable SpO2 finger sensor for adult and pediatric (x1 each)

 14.4 Disposable SpO2 adhesive sensor for neonate (x10)

 14.5 Reusable skin temperature sensor for adult, pediatric and neonate (x1 each)

 14.6 Reusable rectal temperature sensor for neonate (x1)

 14.7 Reusable NIBP hoses for Adult, pediatric and neonate (x1)

 14.8 Reusable NIBP cuff for adult and pediatric (4 sizes)

 14.9 Disposable NIBP cuff for neonate (4 sizes, 10 each)

 14.10Reusable IBP transducer (x1shall be included, unless otherwise requested by client)

 14.11 Disposable IBP kit (x10 shall be included, unless otherwise requested by client)

 15 Mounting:

 15.1 The unit shall be with mounting arm for both screen and module server

 15.2 The mounting arm shall be attached to wall, Bedhead unit or pendant (please refer to

drawings for exact configuration)

 15.3 The unit supplier shall provide all required adapters, interfaces etc for the bracket.

 16 Battery:

 16.1 With internal rechargeable batteries (preferable)

 16.2 Battery run time: 30 minutes

 17 The unit shall include all required accessories, modules, cables, software, licenses etc for full functionality

 18 Price list for all parameter modules and related accessories/consumables shall be provided

 19 The unit shall include original power cable with non-rewirable fused european Standard plug

 20 Shall be CE marked and/or FDA approved

1

5

PATIENT MONITORS

1 The unit shall have the following minimum features:

2 Shall be fully functional for all patient categories: Adult, Pediatric and Neonate

3 Shall be fully modular system, i.e. separated CPU/modules server and display

4 The unit's parameter modules shall be swappable with other patient monitors in the hospital (same modules interface)

5 All surfaces shall be resistant to common disinfectants

6 Display/screen:

6.1 Screen size: 15” Medical grade, LCD color touch screen

6.2 Simultaneous display of 4 channels/waveforms

6.3 With preset and configurable interfaces/layouts

6.4 The order and color of waveforms and numerical parameters shall be user selectable

7 The unit shall include all the required software, modules, parts and accessories to monitor the following parameters:

7.1 ECG and Heart Rate

7.1.1 5 leads monitoring for adults and pediatric

7.1.2 3 lead monitoring for neonates

7.1.3 Heart rate range: 15 – 300bpm

7.2 Basic Arrhythmia detection and classification of different types of arrhythmias for adults and pediatrics

7.3 ST segment analysis: Advanced monitoring and analysis of ST segment deviation for adults and pediatrics

 7.4 SpO2 and Pulse Rate

 7.4.1 Range: 1 –100%

 7.4.2 Shall be compatible with sensors from other manufacturers, including Massimo, and Nellcor

 7.5 Respiration

 7.5.1 Respiration monitoring via impedance calculation, through ECGlead

 7.5.2 Range: 1 – 150bpm

 7.6 Temperature

7.6.1 1channel

 7.6.2 Range: 0 – 45°C

 7.7 Non Invasive Blood Pressure

 7.7.1 Oscillometric method

 7.7.2 with manual and automatic activation

 7.8 Invasive Blood Pressure

 7.8.1 Simultaneous measurement and display of 2channels

 7.8.2 Range: -25 to 360mmHg

 7.8.3 The appropriate interface cables and adapters between the patients monitor and pressure

transducer shall be included (coordinate with the client

 8 The unit shall be capable (software ready) to monitor the followingparameters:

8.1.0 Blood temperature range: 25 – 42°C

 8.2.1 Injectate temperature range: -1 –30°C

 8.3 12 lead ECG monitoring for adult and pediatric with ST analysis for all leads

 8.4 Additional 2 channels for invasive blood pressure

 9 With drug calculation and managementcapability

 10 Networking and connectivity

 10.1 Shall be fully compatible, connectable and interfaced with the anesthesia machine for bidirectional data sharing (interface shall be coordinated supplier)

 10.2 Shall be networkable to share data with hospital networks (bidirectional) such as Hospital Information System (HL7 compliant), Laboratory and PACS as well as with a central monitoring station via Local area Network (LAN) (coordinate with client and IT contractors)

 10.3 Shall facilitate report generation via networked printer and recorder

 11 Trending /Events storage:

 11.1 Numerical and graphical trending: 48 hours

 11.2 Events storage: 50 events minimum

 12 Alarm/self test system:

 12.1 With advanced automatic self test at switch on

 12.2 With alarm history for 72 hours

 12.3 Prioritized (three alarm levels) with audio (tone coded) and visual (color coded) alarming system according to alarm level

 13 The unit, its accessories and modules shall be protected against defibrillation

14 Accessories (the following should be included in the delivery):

 14.1 Reusable ECG cables for adult, pediatric and neonate (x2 each size)

 14.2 Disposable electrodes for adult, pediatric and neonate (x100 each size)

 14.3 Reusable SpO2 finger sensor for adult and pediatric (x2 each)

 14.4 Disposable SpO2 adhesive sensor for neonate (x50pcs)

 14.5 Reusable skin temperature sensor for adult, pediatric and neonate (x2 each size)

 14.6 Reusable rectal temperature sensor for neonate (x2 each)

 14.7 Reusable NIBP hoses for Adult, pediatric and neonate (x2 each size)

 14.8 Reusable NIBP cuff for adult and pediatric and neonate (x4 each size)

 14.9 Disposable NIBP cuff for neonate (4 sizes, 10 each)

 14.10 Reusable IBP transducer (x1 should be included)

 14.11 Disposable IBP kit (x10 should be included)

 15 Mounting:

 15.1 The unit shall be with mounting arm for both screen and module server

 15.2 The mounting arm shall be attached to wall, Bedhead unit or pendant (please refer to

drawings for exact configuration)

 15.3 The unit supplier shall provide all required adapters, interfaces etc for the bracket.

 16 Battery:

 16.1 With internal rechargeable batteries (mandatory)

 16.2 Battery runs time: 4hours

 17 The unit shall include all required accessories, modules, cables, software, licenses etc for full functionality

 18 Price list for all parameter modules and related accessories/consumables should be provided

 19 The unit should include original power cable with non-rewirable fused European Standard plug

 20 Shall be ISO, CE marked and/or FDA approved

5

6

 Portable oximeter(Handheld Portable Vital signs Patient Monitor)

Description: Hand Held Portable Vital signs Patient Monitor

Product Specifications:

Handheld, or mobile stand mounting

  • Simultaneous measurement NIBP, SpO2, pulse, temperature
  • Plethysmograph display
  • Selectable, adult / pediatric / neonatal mode
  • Variable parameter selection
  • Data review
  • Trend
  • 100 patient data storage
  • Support audio and visual alarm,support to set alarm upper and lower limit values
  • Lithium ion battery (8 hours) power supply
  • Two measurements mode: Spot, Monitoring
  • Data storage capabilities,support for historical data view and trend chart 

back to see

  • In monitoring mode,can continuously record 48 hours of measurement data
  •  In spot mode,100 users ID, each user can store 200sets data
  • Supplied with charging dock

NIBP

NIBP measurement range, Pulse rate range: 40~240bpm

NIBP measurement accuracy: ± 3mmHg

Pulse rate measurement accuracy: <=2% (>=100 BPM) or 2 beats/min (<100 BPM)

Independent software protection pressure | Adult: 300mmHg | PED:240mmHg | NEO:150mmHg

Independent hardware protection pressure | Adult: 320-330mmHg | PED: 265-275mmHg | NEO: 160-165mmHg

Oxygen Saturation (%SpO2)

Measurement range: SpO2: 0-100% | PR: 0-254bpm | Rerfusion index: 0.05%-20% | SpO2 saturation: 70-100% | Pulse rate: 20-254BPM | Perfusion Index: 0.025%-20%

Measurement accuracy: SpO2: Adult (Including pediatric) + 2 digit (70-100%) not defined (70%) | Neonate +3digits | not defined (<70%) | Perfusion Index: 0.05%-20%

Resolution: SpO2 saturation: 1% | Pulse rate: 1BPM

Temperature

Measurement range: 25-45°C

Resolution: 0.1°C

Accuracy: 0.1°C

Battery: Lithium ion Operation time: 8 hours for normal operation

Temperature: Operating: 0°C~45°C Storage / Transportation: -20°C~65°C

Humidity: Operating: 15% to 90% no condensing Storage: 0% to 95% no condensing

Altitude: Operating Altitude: Up to 5000 Meters

Size: 146mm x 67mm x 30mm (Weight 250g)

6

7

OXYGEN CYLINDER 10 LITERS WITH ROLLING STAND AND WITH OXYGEN REGULATOR

  •  Small Oxygen Cylinder (10L) with O2 Regulator (Bull nose, Cylinder Type) & Humidifier   Bottle
  •  Unit to be manufactured from Mild steel with a chip resistant epoxy power coat finish.
  •  Unit to be provided with a portable oxygen cylinder trolley (transport cart) with a locking   bar or chain to secure bottle in place.
  •  Unit to be mounted on two 100mm non-marking castors.
  •  Unit to provide a handle to allow for safe handling and movement of trolley with bottle   locked in place.
  •  Unit to include the supply of a Bull nose fitting Oxygen regulator complete with gauges   (DIN system)
  •  Unit to include Humidifier bottle
  •  Hand open/close oxygen clylinder regulator valve
  •  Working pressure : 150 kpa
  •  Testing pressure: 250kpa

4

8

DIN standard Oxygen flowmeter with humidifier bottle

Technical Specifications:

  • Flowmeter must be of the pressure compensated type.
  • Calibrated for 0 to 15 litres per minute.
  • Must have a flow accuracy within 10%.
  • The range of 0 – 15 l/m of the flowmeter must be permanent and easy to read.
  • The flowmeter must have a stainless steel float in the calibrated flow tube
  • The control knob of the flowmeter must be colour coded white for oxygen and must be clearly marked ‘Oxygen’.
  • The control knob must be large and easy to grip.
  • The flowmeter must operate accurately on a 4 bar pipeline source.
  • The flowmeter must come standard with probe and have a standard 9/16” – 18 TPI male threaded outlet connector.
  • The flowmeter must be fitted to a back bar not wider than 150mm and when plugged into the wall point, should not extend by more than 120mm.
  • The flowmeter hood must be made of crack–resistant polycarbonate.

32

9

Venturi Suction regulators with 2L suction bottles

  • Sizes: 89x123x141mm
  • maximum suction flow: 27 L/min. ±2 L/min. at -775 mbar
  • vacuum gauge: 0 ÷ -1000 mbar
  • maximum adjustable depression (with plate pressure ±10%): -800 mbar -25 mbar
  • air consumption at the maximum suction value: 60 L/min. ±2 L/min.
  • Standard inlet connection: DIN
  •  Suction bottles: capacity 2L with wall mountable handle and accessories

32

10

Splints for legs

Care kit features versatile Iimb splints that can be used as lefts or rights, Kit includes adult arm splint, adult leg splint arm/shoulder immobilizer, child arm splint, child

Leg splint, straps and a carrying case. X-ray Translucent and MRI compatible

Model Packing size, YXH-9 92 x 36 x 16cm (1pcs/carton)

 N.W. 1.5kg, G.W. 2kg

10

11

Splints for arms

Double Fixation Wrist Brace for Carpal Tunnel, ,Adjustable Night Time Forearm Immobilizer Brace Splints,9.8 inch

Technical Specification:

  • Provide stabilization and enhance casualty comfort
  • Suitable for suspended fractures of the arm & leg
  • Available in full arm, full leg and Half arm, Half leg sizes.
  •  Pressure on the limb can be controlled by opening or closing the pull push valve
  • Splints are transparent to allow observation of the injured limb.

10

12

Spinal board

This product is ideal for providing support during the transport of patients where spinal injuries or limb injuries are suspected. A Single piece high density polyethylene, rigid light and portable, corrosion free , non-permeable to liquids, must be able to clean with soap and water , X-ray and MRI compatible, net weight not more than 9 kgs, load capacity more than 155kg,Length ( 180-195cm) width (40 -45cm) Height (3-6 cm), head blocks with straps, 4 pair strips with latches and clips

13

Spinal scoop board

The requested spinal scoop board should respond to the requirements like dimensions (length 1640mm, width 430mm, height 80mm),

Material (shock absorbent, floatable), weight (maximum 9kg), and

Features:

Hinged Ends: The board should be hinged at both ends to allow for a scoop-like design, enabling easier patient positioning.

Carrying Handles: Handles on all sides facilitate transportation.

Restraint System: A restraint system should be included to secure the patient.

Straps: Spiderman straps (or similar) should be included, with color-coded and X-ray compatible straps, adjustable in length.

Head Immobilizer: A head immobilizer is optional but can be a valuable addition.

X-ray Compatibility: The board should be X-ray compatible to allow for radiological examination of the patient.

Packaging:

The scoop stretcher should be packaged in polyethylene bags for easy storage.

Certificates:

The vendor should provide relevant certificates, such as a manufacturer's test certificate, to demonstrate compliance with the specifications.

Warranty:

The product should come with a warranty, typically 2 years from the date of supply.

Self-life:

The scoop stretcher should have a minimum self-life of 5 years.

2

14

Head immobilizer

Immobilization Devices: Head immobilization device, Cervical collars for adult and pediatric use small, medium and Large (Philadelphia type)

3

15

Adult weighing scale seating type (Big size)

General description:

Electronic Weighing Scale, sitting type

Have 4 steering wheels of which are 2 fitted with brakes,

The chair scale should be moved into the smallest corner without any effort.

The foldable footrests allow a trouble-free access for the patient.

The patted arm rests and the ergonomically seating position must make the scale comfortable to use.

Technical specification:

  • Capacity: 100kg- 250 kg
  • Graduation:
  • Dimensions: 600 x 850 x 960 mm
  • Weight; Seat size: 380 x 450 mm / seat height 490 mm
  • Functions: Automatic zero setting, tare, pre-tare, low battery indication, auto witch off, hold, BMI,
  • Have a condrol panel with digital display
  • Have built-in battery
  • Have battery charger
  • Possible to use while charging
  • The unit shall include original power cable with non-rewirable fused European

Standard

  • Shall be CE marked and/or FDA approved
  • Manufacturer and Supplier should have ISO 13485 certification for quality standards.
  • Warranty: 2 years, all spares provided

2

16

PAEDIATRIC WEIGHING SCALE

(i) Balance Baby (Electronic Digital Weighing Scale)

Electronic digital scale with a large pan with stable base. Capacity Up to 20 kg with a provision for measuring height (Up to 100 cm) on the side.

Accuracy +/-1 gm. Large LCD display for reading. Easy to Clean.

Note for all scale weighing , calibration check should be done once half yearly

2

17

1 STOOLS, ADJUSTABLE NURSING

1.1 Pneumatic lift mechanism for seat height adjustment

1.2 Articulated backrest with height adjustment

1.3 Approximate hydraulic height Adjustment: 500mm-700mm.

1.4 Removable padded armrests

1.5 Seat and backrest are contoured for extra comfort and made from high-density foam

1.6 Upholstery material: disinfectant-tolerant, stain and flame resistant

1.7 Five leg base

1.8 Approximate base diameter: 550 mm

1.9 Swivel casters with approximate diameter of 50mm

1.10 The stool is non-colouring to the floor

1.11 Colour is subject to selection and approval by the Client.

2 STOOLS, ADJUSTABLE, SURGEONS (1pc)

2.1 Foot operated pneumatic lift mechanism for seat height adjustment

2.2 Saddle-shaped seat preferable

2.3 Adjustable padded backrest with height and depth adjustment

2.4 Removable padded armrests

2.5 Approximate diameter of seat: 400mm

2.6 Approximate hydraulic height Adjustment: 500mm-800mm.

2.7 Seat and backrest padding made from high-density foam

2.8 Upholstery material: disinfectant-tolerant, stain and flame resistant

2.9 The whole stool shall be electrically conductive

2.10 High stability stainless steel base.

2.11 Anti-static, twin-wheel, swivel casters

2.12 Colour is subject to selection and approval by theClient.

3 STOOLS, ANESTHETISTS (1)

3.1 Pneumatic lift mechanism for seat height adjustment

3.2 Saddle-shaped seat preferable

3.3 Adjustable backrest with height and depth adjustment.

3.4 Padded backrest

3.5 Approximate hydraulic height Adjustment: 500mm-800mm.

3.6 Seat, backrest padding made from high-density foam

3.7 Upholstery material: disinfectant-tolerant, stain and flame resistant

3.8 The whole stool shall be electrically conductive

3.9 High stability stainless steel base with foot-rest

3.10 Five anti-static, twin-wheel, swivel casters

3.11 Colour is subject to selection and approval by theClient.

2

18

THEATRE TROLLEYS (DIFFERENT SIZES)

Medical dressing Trolley / CARTS, DRESSING

General requirement

1 Polished Stainless Steel tubular frame mounted on four castors

 2 All the Stainless Steel should be seamless conforming to 304 grade/ 18 gauge and polished finished.

 3 Two Stainless Steel shelves with protective railings on three sides.

 4. One drawer under top shelf.

 5 Anti-static swivel casters, 75mm diameter

a) TROLLEY, DRESSING – MEDIUM S/S - Quantity: 2

1 BASIC REQUIREMENTS

1.1 A trolley for storage of dressings. 

2. TECHNICAL SPECIFICATION:

2.1 The trolley to be manufactured from 12-25mm polished stainless framework (round or square tubing).

2.2 The frame above the top and lower shelf to have a guardrail on three sides.

2.3 Trolley to be supplied with two stainless steel removable flush mounted shelves.

2.4 The shelves to be mounted on anti-static sound deadening buffers.

2.5 The height of the top shelf to be 86cm from floor level, with the lower shelf approximately 300-350mm from floor level.

2.6 The shelf size to be approximately 46x62cm.

The trolley to be mounted on four x 75/100mm swivel anti-static castors

b) TROLLEY, DRESSING – LARGE 1 DRAWER S/S - Quantity:

1 BASIC REQUIREMENTS

1.2 A trolley for storage of dressings. 

2. TECHNICAL SPECIFICATION:

2.1 The trolley to be manufactured from 12-25mm polished stainless framework (round or square tubing).

2.2 The frame above the top and lower shelf to have a guardrail on three sides.

2.3 Trolley to be supplied with two stainless steel removable flush mounted shelves.

2.4 The shelves to be mounted on anti-static sound deadening buffers.

2.5 Overall approximate dimensions (L x W x H): 600mm x 450mm x 920mm

2.6 The trolley to have one drawer manufactured from pressed stainless steel or Epoxy Coated with integral handle.

2.7 Drawer unit to have a device to prevent accidental / complete removal of the drawer unit.

2.8 The trolley to be mounted on four x 75/100mm swivel anti-static castors

3

19

EXAMINATION LAMP

1. BASIC REQUIREMENTS.

A mobile LED examination light mounted on a rolling stand with at least 5x50mm castors.

2. TECHNICAL SPECIFICATION:

2.1 Lamp wattage: +/- 35 watts.

2.2 Dual voltage: 12 volts (high intensity), 10 volts (low intensity).

2.3 Colour temperature: 3 000 Kelvin (high intensity), 2 868 Kelvin (low intensity).

10 000 Peak Lux at 60 cm.

2.4 Face lumens (all light collected out of the face of the lamp: 645 (high intensity), 366 (low intensity).

2.5 Lamp life: +/-50000 continuous hours.

2.6 Beam spread: 20 degrees.

2.7 Spot size at:

  • Working distance of 30 cm = 12,5 cm.
  • Working distance of 40 cm = 17,5 cm.
  • Working distance of 50 cm = 23,7 cm.
  • Working distance of 60 cm = 28,7 cm.

2.8 Flexible arm length: 60 cm and pole height of 75 cm.

2.9 Base diameter: 35 cm mounted on 5 swivel castors of at least 50 mm diameter.

3. POWER REQUIREMENTS.

The examination light must operate on a mains supply of 220 volt – 50 Mhz cycle.

2

20

Mobile LED Operating light ( NB: not ceiling )

QTY: 1

Diameter of light head (cm /inch):

>50/20

The light shall have a single touch "all off" available both on the lights handle

The light pendants shall have a cover to conceal the mount

Illumination (lx)

-10 to 50 C

Operating temperature

>100

Supply voltage range

120 – 270 AC, 50Hz

Power Factor

>0.9

If the LEDs fails during operation the emergency LED automatically swivels in the position and continues or it should have an emergency bypass option.

It shall have an option against surcharge

The lamp shall have electronic light intensity control, to be adjustable between 50% and 100% with an indicator like a LED

 Light color

 Cool white

LED service life

>50,000 Burning Hrs

Usage

Continuous

The one head light shall have a wide range of movement (rotation)

Number of LEDs

60-80

Simple replacement of the LED

Movable with lockable casters

Focus (controls) should be sterile adjustable

Kind

Any surgery

1

21

COMMODE CHAIR

1. BASIC REQUIREMENTS.

A commode for use by patients.

2. TECHNICAL SPECIFICATION:

2.1 The commode to be manufactured from tubular (Round or square) mild steel framework with an epoxy coated white paint finish. 

2.2 The backrest and removable seat to be upholstered in fire retardant easily cleanable material.

2.3 The seat to be removed to reveal a plastic toilet seat with a cage / device below to hold a bedpan.

2.4 The commode to be supplied with one stainless steel bedpan.

2.5 The commode to be mounted on 4 x 100-125mm swivel castors of which two should have a locking mechanism.

2.6 Unit to conform to all relevant safety and manufacturing or CE standards as applicable.

 .

2

22

DRIP STAND, MOBILE

BASIC REQUIREMENTS

The drip stand to be mobile on five start castor base, with two to four infusion hooks mounted on an extendable infusion pole.

TECHNICAL SPECIFICATION:

1.1 The drip stand to support up four infusion fluid bags.

1.2 Stand to be manufactured from mild steel and either powder or epoxy coated white.

1.3 Unit to be height adjustable and have a suitable locking mechanism.

1.4 Unit to be mobile on either three or five anti-static swivel castors of at least 40mm diameter.

1.5 Unit to incorporate a top cross bar with hook to support two infusion bags.

20

23

Theatre bins: Standard theatre bins with minimum of 20L, User to confirm sample

24

Oxygen regulator

TECHNICAL SPECIFICATION BULLNOSE OXYGEN REGULATOR:

2.1 A medical gas regulator incorporating a flow meter

2.2 To have a Bull nose fitting for an oxygen cylinder.

2.3 To have a hand wheel type connection, cylinder pressure gauge and 3/8” BSP outlet.

2.4 To incorporate a safety pressure relief valve.

2.5 The flow meter to be manufactured from an impact resistant plastic with flow adjustment

knob.

2.6 Flow meter to be graduated from 1 to 15 litres per minute.

2.7 Regulator to be manufactured according to relevant international standards.

5s

25

Working instrument trolley:

General requirement

1 Polished Stainless Steel tubular frame mounted on four castors

 2 All the Stainless Steel should be seamless conforming to 304 grade/ 18 gauge and polished finished.

 3 Two Stainless Steel shelves with protective railings on three sides.

 4. One drawer under top shelf.

 5 Anti-static swivel casters, 75mm diameter

Size: 850x550x950

7

26

Vein finder: Should be supplied with standing trolley/holder

  • Infrared Wavelength: 760-940nm
  • Detection Depth: 0-10mm
  • Best Detection Distance: 18-26cm
  • Accuracy: ±0.3mm (blood vessel position), ≤0.3mm (blood vessel resolution)
  • Power Supply: Input 100V-240V 50Hz-60Hz AC, Output 5V 2A DC
  • Battery Life: 3 hours continuous working time
  • Weight: 280g
  • Dimensions: 20cm(L) x 6.2cm(W) x 5.5cm(H)

2

 

Click on the APPLY button to send your application documents:
  • Your application will be sent to the employer immediately (Allowed formats: .doc .pdf .txt .docx)
  • A confirmation email will be sent to you few minutes afterwards
  • You can request any documents archived from our website (ex: a job description, a CV, a cover letter...)